Product Details
AMI5~40kg Installation diagram
AMI 50~500kg Installation diagram
FEATURES:
●Capacity: 5kg to 40kg
●Compact structure,easy installation
●OIML C3 approval
APPLICATION:
●Pricing scale, counting scale, barcode scale, etc.
●Variety kinds of press testing devices

Rated capacity
|
L
|
L1
|
L2
|
H
|
W
|
W1
|
T
|
5,8,10,15,20,30,35,40kg
|
130
|
106
|
28
|
21.5
|
24.5
|
15
|
M6
|
SPECIFICATION:
|
|
Rated capacity: 5kg to 40kg
|
Ultimate safe overload:300%Emax
|
Rated output:2.0±0.2mv/v
|
Recommended Excitation:10V DC
|
Combined error:OIML C3
|
Maximum Excitation:15V DC
|
Zero balance: ±3%Emax
|
Environment protection: IP65
|
Creep error(30minutes):±166ppm
|
Input impedance: 404±15Ω
|
Temperature effect on zero: ±17.5ppm/℃
|
Output impedance: 350±3Ω
|
Temperature effect on output: +20℃~+40℃,±17.5ppm/℃
|
Insulation resistance at 50V DC: ≥2000MΩ
|
-10℃~+20℃,±11.67ppm/℃
|
Material: Aluminium
|
Compensated temperature range: -10℃~+40℃
|
cable length: 0.5meter, diameter Φ5mm
|
Operating temperature range: -20℃~+50℃
|
Max.platform size:300×300mm
|
Maximum safe overload:150%Emax
|
Installation torque,recommended:10N.m
|
FEATURES:
●Capacity: 50kg to 500kg
●Compact struture, easy installation
●OIML C3 approval
APPLICATION:
●Platform Scale
●Variety kinds of press testing device.

Rated capacity
|
L
|
L1
|
L2
|
L3
|
H
|
W
|
W1
|
50,100,150,200,250,300,500kg
|
150
|
25.4
|
86.6
|
38
|
37.5
|
37.5
|
25.4
|
SPECIFICATION:
|
|
Rated capacity: 50kg to 500kg
|
Ultimate safe overload:300%Emax
|
Rated output:2.0±0.2mv/v
|
Recommended Excitation:10V DC
|
Combined error:OIML C3
|
Maximum Excitation:15V DC
|
Zero balance: ±3%Emax
|
Environment protection: IP65
|
Creep error(30minutes):±166ppm
|
Input impedance: 404±15Ω
|
Temperature effect on zero: ±17.5ppm/℃
|
Output impedance: 350±3Ω
|
Temperature effect on output: +20℃~+40℃,±17.5ppm/℃
|
Insulation resistance at 50V DC: ≥2000MΩ
|
-10℃~+20℃,±11.67ppm/℃
|
Material: Aluminium
|
Compensated temperature range: -10℃~+40℃
|
cable length: 1.8meter, diameter Φ5mm
|
Operating temperature range: -20℃~+50℃
|
Max.platform size:400×400mm
|
Maximum safe overload:150%Emax
|
Installation torque,recommended:10N.m
|
|