UDA
Product Details
UDA Installation diagram
FEATURES:
●Capacity: 50kg to 1t
●Compact structure, easy installation
●OIML C3 approval
APPLICATION:
●Big size platform scale
●Variety kinds of press testing device

Outline Dimension:
|
|
Rated capacity
|
L
|
L1
|
L2
|
L3
|
H
|
W
|
W1
|
T
|
|
50,100,150,200,250,300,500,750,800kg,1t
|
174
|
19
|
122
|
42
|
63.5
|
59.5
|
30
|
M8
|
|
|
SPECIFICATION:
|
Rated capacity: 50kg to 1t
|
Recommended Excitation:10V DC
|
Rated output:2.0±0.2mv/v
|
Maximum Excitation:15V DC
|
Combined error: OIML C3
|
Environment protection: IP65
|
Zero balance: ±3%Emax
|
Input impedance: 404±15Ω
|
Creep error(30minutes):±166ppm
|
Output impedance: 350±3Ω
|
Temperature effect on zero: ±17.5ppm/℃
|
Insulation resistance at 50V DC: ≥2000MΩ
|
Temperature effect on output:
+20℃~+40℃,±0.0175%F.S/10℃
-10℃~+20℃,±11.67ppm/℃"
|
Material: Aluminum
|
Compensated temperature range: -10℃~+40℃
|
cable length: 1.8meter, diameter Φ5mm
|
Operating temperature range: -20℃~+50℃
|
Max. platform size:600×600mm
|
Maximum safe overload:150%Emax
|
Installation torque, recommended:
25N.m(50kg~300kg),30N.m(500kg~1t)
|
|