EDS Installation diagram
FEATURES:
●40t Capacity
●Steel ball loading, reset ability strong
●The whole installation is convenient, and the weighing accuracy is high.
●stainless steel, alloy steel
●Fixed joint(EDSC),Single aviation plug(EDSB),double aviation plug(EDS)
●Alloy steel
APPLICATION:
●Truck scale
●Railway scale
●Blending scale and A variety of scales
Outline Dimension
|
Rated capacity(t)
|
L
|
L1
|
L2
|
W
|
W1
|
H
|
H1
|
H2
|
C1
|
C2
|
C3
|
C4
|
40
|
240
|
80
|
52
|
135
|
100
|
240.7
|
11
|
18.5
|
Φ88
|
Φ30
|
Φ18
|
Φ76.2
|
SPECIFICATION:
|
|
Rated capacity: 40ton
|
Maximum safe overload: 150% OF R.C
|
Combined error: ±0.02% F.S
|
Ultimate safe overload: 200% OF R.C
|
Non-repeatability: ±0.01% F.S
|
Recommended Excitation: 9 to 12V DC
|
Non-linearity: ±0.02% F.S
|
Environment protection: IP69K
|
Hysteresis error: ±0.02% F.S
|
Communication BPS: 9600/19200
|
Temperature effect on zero: ±0.015% F.S
|
Communication Mode: RS 485
|
Temperature effect on output: ±0.015% F.S
|
Material:alloy steel;Stainless Steel
|
Compensated temperature range: -10 to +40℃
|
Cable: 16 meter,diameterφ8.8mm
|
Operating temperature range: -30 to +70℃
|
|